Max Diameter of Workpiece: | 1000mm |
---|---|
Mass Scope of Workpiece: | <900kg |
Type: | Full Scale Formaldehyde Emission Test Chamber |
Maxcapacity: | >1000KN |
Accuracy Grade: | 0.5 |
Load Way: | Electronic Load |
Customization: |
---|
Suppliers with verified business licenses
Full Scale Formaldehyde Emission Test Chamber
Model | VOC-3000 | VOC-5000A | VOC-8000 | VOC-10000 | VOC-12000 | VOC-15000 | VOC-24000 | VOC-30000 | VOC-72000 |
Environment temperature |
5ºC~35ºC | ||||||||
Environment humidity |
≤90%RH | ||||||||
Environment requirements |
With no pollution source,TVOC≤500ug/m³ | ||||||||
Size of climate Chamber (W×D×H)mm |
1500×1350×1500 | 1670×1500×2000 | 2000×1600×2500 | 2500×1600×2500 | 3000×1600×2500 | 3200×2000×2500 | 3000×3200×2500 | 3000×4000×2500 | 3000×6000×4000 |
Size of chamber door (H×W) mm |
1200×800 | 1800×900 | 1900×900 | 1900×1100 | |||||
Temperature adjustment range |
15ºC~40ºC,more than 70ºC for high-temperature cleaning | ||||||||
Humidity Adjustment range |
40~60%RH (20~30ºC) | ||||||||
Pressure | 10 ±5pa | ||||||||
Temperature fluctuation |
±0.3ºC | ||||||||
Temperature deviation |
±0.5ºC | ||||||||
Humidity fluctuation |
±2.5%RH | ||||||||
Humidity deviation |
3% | ||||||||
Air exchange rate |
0.2~5 times/h ±5%(0.2-3times/h ±5% optional) | ||||||||
Air velocity | 0.1m/s~0.3m/s | ||||||||
Power supply | AC 380V/50Hz/Three-phase four-wire/five-wire | ||||||||
Start-up power | 25kw | 30kw | 36kw | 44kw | 50kw | 55kw | 65kw | 93kw | |
Running power | 12kw | 13kw | 14.8kw | 17.9kw | 20kw | 22kw | 26kw | 38kw | |
Background Concentration Of formaldehyde |
Less than 15ug/m³,minimum value:6ug/m³ | ||||||||
Recovery rate |
More than 90% | ||||||||
Air Purification system |
Standard configurations | ||||||||
Size of climate chamber |
Customized |
GB18580- 2001 |
Indoor Decorating and Refurbishing Materials-Limit of Formaldehyde Emission of Wood-Based Panels and Finishing Products |
GB18584- 2001 |
Indoor Decorating and Refurbishing Materials-Limit of Harmful Substances of Wood Based Furniture |
GB18587- 2001 |
Indoor Decorating and Refurbishing Materials-Limitations of Harmful Substances Emitted Form Carpets,Carpet Cushions and Adhesives |
ASTM D6007-02 |
Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using A Small Scale Chamber |
ENV717-1 | Wood-Based Panels.Determination of Formaldehyde Release.Formaldehyde Emission by the Chamber Method |
HJ571- 2010 |
Technical Requirement for Environmental Labeling Products Wood Based Panels and Finishing Products |
HJ566- 2010 |
Technical Requirement for Environmental Labeling Products Wooden Toys |
Upholstered Furniture Limits Harmful Substances from Sofa (Exposure Draft) and Climate Chamber for Detection of Volatile Organic Compounds in Furniture(Exposure Draft) | |
LY/T1980- 2011 |
Determination Device of the Emission of Volatile Organic Compounds and Formaldehyde |
LY/T1981- 2011 |
Testing Apparatus for Formaldehyde Emission by the Gas Analysis Method |
LY/T1982- 2011 |
Large Chamber for Formaldehyde Emission of Wood-Based Panels and Its Products |
Suppliers with verified business licenses