Simulated Environmental Equipment Constant Temperature and Humidity Testing Chamber

Max Diameter of Workpiece: 1200mm
Mass Scope of Workpiece: <900kg
Type: Universal Testing Machine
Maxcapacity: <1000KN
Accuracy Grade: 0.5
Load Way: Electronic Load
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GTH-150
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC380V
Oil Cylinder Position
Under
Inner Chamber Size(W*H*D)
500*600*500mm
Temperature Range
-70 Degrees to 180 Degrees
Humidity Range
20%~98%Rh
Temp. & Humidity Fluctuation
+/-0.2degree,+/-0.5%Rh
Temp.&Humidity Resolution
0.01degree,0.1%Rh
Exterior Chamber Material
Stainless Steel Plate + Powder Coated
Interior Chamber Material
SUS#304 Stainless Steel Plate
Certificate
Ce Certificate, Pass SGS&TUV&BV Audit
Transport Package
Strong Plywood Carton
Specification
950*1500*1050mm
Trademark
Grande
Origin
China
HS Code
9001100001
Production Capacity
200 Set/Month

Product Description

Simulated Environmental Equipment Constant Temperature and Humidity Testing Chamber


Programmable Temperature and Humidity Test Chambers
Temperature and Humidity Test Chambers provides an economical and space-saving solution for a variety of testing requirements. It can simulate different climatic conditions, such as heat-endurance, cold-endurance, dryness-endurance, and humidity-endurance, which defines the performance of material. By testing the product under different climatic conditions to see whether its performance can meet the intended requirements. It is widely applied in the industries of electron, electrical equipment, vehicle, metal, food, chemistry, building materials, luggage, adhesion tape, printing, packaging, and other product components and materials.
The programmer includes a temperature alarm as just one part of Grande's Three-tiered over-temperature protection system. A thermal fuse and a user-set independent limit are also included. In addition, a specimen power terminal allows the user to safely operate powered equipment inside or with the chamber.
Corresponding Standard of the Temperature and Humidity Test Chamber:
1.GB11158 high-temperature testing condition
2.GB10589-89 low-temperature testing condition
3.GB10592-89 high-low-temperature testing condition
4.GB/T10586-89 humidity testing condition
5.GB/T2423.1-2001 low-temperature testing condition
6.GB/T2423.2-2001 high-temperature testing condition
7.GB/T2423.3-93 humidity testing condition
8.GB/T2423.4-93 alternating temperature testing machine
9.GB/T2423.22-2001 temperature testing method
10.IEC60068-2-1.1990 low-temperature testing method
11.IEC60068-2-2.1974 high-temperature testing method
12.GJB150.3 high-temperature test
13.GJB150.4 low-temperture test
14.GJB150.9 humidity test
 

Grande Expertise in Humidity Control

Controlling humidity in a small environmental chamber can be especially challenging. Grande expertise in humidity control brings intelligent design that is carefully integrated into the Criterion chambers. The humidity subsystems are designed for reliability, convenience, and performance:
  • An external steam generator allows expanded range and is easy to maintain.
  • A separate de-humidification coil improves low humidity control and range.
  • Wet-bulb humidity sensor is a "primary measurement method" for accuracy. It is also economical, easy to maintain, and reliable because it has no risk of failure due to over-saturation. (Read why analog is preferred over digital.)
  • Direct water supply connection is standard, with options for water filtering and recirculating water tank.
Features
  • High performance and quiet operation (65 dBa)
  • Space-saving footprint, designed for flush installation to wall
  • Stainless steel exterior
  • Full thermal break around doorframe
  • One 50mm (2") diameter cable port on left, with flexible silicone plug
  • Three levels of overheat protection, plus overcool protection
  • Easy lift-off service panels, electrical access on left
  • Detachable eight-foot power cord with plug
  • Direct water supply connection for continuous operation (supply tank optional)
  • Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp.
 

Touch-screen programmer/controller with Ethernet

  • Watlow F4T with touch-screen and Ethernet port standard
  • Save 120 profiles with up to 1200 steps each (ramp, soak, jump, auto-start, end)
  • One event relay for external device control, plus specimen power interlock relay for safety
  • Grande exclusive options include: Web Controller for full remote access; Chamber Connect software for basic data logging and monitoring. USB,RS-232 and RS-485 ports available, as well.
Technical parameters:
Model No  GTH-080 GTH-150 GTH-225 GTH-408 GTH-800 GTH-1000
Working room(L) 80 150 225 408 800 1000
Inner chamber size(mm)W*H*D 400*500*400 500*600*500 500*750*600 600*850*800 1000*1000*800 1000*1000*1000
Exterior chamber size(mm)W*H*D 900*900*1500 950*1500*1050 950*1650*1150 1050*1750*1350 1450*1900*1350 1450*1900*1550
Packaging volume(CBM) 2 3 3.5 4.5 5.5 6
G.W.(KGs) 300 320 350 400 600 700
Performance Temperature range -80ºC,-73ºC,-60ºC,-40ºC,-20ºC,0ºC,+150ºC,+180ºC,+200ºC
Humidity range 20%RH ~98%RH(10%RH ~98%RH or 5%RH ~98%RH)
Temp.&Humi fluctuation ±0.2°C, ±0.5%RH
Temp.Humi.Uniformity ±1.5°C; ±2.5%RH(RH≤75%),±4%RH(RH>75%) No-load operation,After stead state 30 min.
Temp.humi resolution 0.01°C; 0.1%RH
Heating up time °C 100       150
Min 30   40 30   40 30   45 30   45 30   45 30   45
Cooling down time °C 0   -20  -40  -60  -70
Min 25      40        50        70        80
Heating rate ≥3°C/min
Cooling rate ≥1°C/min
Material Inner chamber material SUS#304 stainless steel plate
Exterior chamber material SUS304 Stainless steel plate+ powder coated
Insulation Material PU & Fiberglass wool
System Air circulation system Cooling fan
Fan Sirocco fan
Heating System SUS#304 stainless steel high-speed heater
Air flow Forced Air Circulation(It enters at bottom and leaves at top)
Humidification system Surface evaporation system
Refrigeration system Imported compressor,Tecumseh compressor,finned type evaporator,air(Water)-cooling condenser
Refrigerating fluid R23/ R404A USA Honeywell.
Condensation Air(Water)-cooling condenser
Dehumidifying system

ADP critical dew point cooling/dehumidifying method

Controlling system

PID Digital electronic indicators+S.S.R.With PID automatic calculation capability

Operation interface

Grande Expertise in Temperature & Humidity Controller,Chinese-English Shift.

Controller Programmable capability Save 120 profiles with up to 1200 steps each
Setting range Temperature:-100ºC+300ºC
Reading accuracy Temperature:0.01ºC
Input PT100 or T Sensor
Control PID control
Communication interface Equipped with standard communication interface devices USB,RS-232 and RS-485,enable the test chamber to be connected with personal computer(PC),to achieve multi-machine control and management at the same time.Standard: USB external memory port.Optional: RS-232, RS-485, GP-IB, Ethernet
Print function Japan Yokogawa Temperature Recorder(Optional accessories)
 Auxiliary Limit Alarm,Self Diagnosis,Alarm Display(Failure Cause),Timing device(Automatic Switch)
Accessories Multi-layer vacuum glass observation window,Cable port(50mm),Controlling status indicator lamp,Chamber light,Specimen loading shelf(2pcs,position adjustable),Guaze 5pcs,Operation manual 1 set.
Safety protection device Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp.
Power supply AC 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50Hz
Customized service Welcome to Non-standard,Specail requirements,OEM/ODM orders.
The technical information will be subjected to change without notice
 
Optional accessories
1,Low Humidity and Dehumidifying sytstem.
2,Inner glass door with manual operating ports.
3,Temp./Humi.Recorder.
4,Pure water treatment device
5,RS-485 interface can be linked to Personal computer(PC) and achieve multi-level control & recording software management.
6,Liquid nitrogen(LN2)/Liquid Carbon Dioxide(LCO2) fast cooling-down system.
7,Temperature change rate on average without load(Linear heating up and cooling down);5ºC/min,10ºC/min,15ºC/min,
15ºC/min,20ºC/min,25ºC/min,RAMP function.







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.