Warranty: | 1 Year |
---|---|
Product Name: | Full Scale Voc Emission Test Chamber |
Environment Temperature: | 5ºC~35ºC |
Environment Humidity: | ≤90%Rh |
Pressure: | 10±5PA |
Humidity Adjustment Range: | 40~60%Rh(20~30ºC) |
Customization: |
---|
Suppliers with verified business licenses
Model | VOC-3000 | VOC-5000A | VOC-8000 | VOC-10000 | VOC-12000 | VOC-15000 | VOC-24000 | VOC-30000 | VOC-72000 |
Environment temperature |
5ºC~35ºC | ||||||||
Environment humidity |
≤90%RH | ||||||||
Environment requirements |
With no pollution source,TVOC≤500ug/m³ | ||||||||
Size of climate Chamber (W×D×H)mm |
1500×1350×1500 | 1670×1500×2000 | 2000×1600×2500 | 2500×1600×2500 | 3000×1600×2500 | 3200×2000×2500 | 3000×3200×2500 | 3000×4000×2500 | 3000×6000×4000 |
Size of chamber door (H×W) mm |
1200×800 | 1800×900 | 1900×900 | 1900×1100 | |||||
Temperature adjustment range |
15ºC~40ºC,more than 70ºC for high-temperature cleaning | ||||||||
Humidity Adjustment range |
40~60%RH (20~30ºC) | ||||||||
Pressure | 10 ±5pa | ||||||||
Temperature fluctuation |
±0.3ºC | ||||||||
Temperature deviation |
±0.5ºC | ||||||||
Humidity fluctuation |
±2.5%RH | ||||||||
Humidity deviation |
3% | ||||||||
Air exchange rate |
0.2~5 times/h ±5%(0.2-3times/h ±5% optional) | ||||||||
Air velocity | 0.1m/s~0.3m/s | ||||||||
Power supply | AC 380V/50Hz/Three-phase four-wire/five-wire | ||||||||
Start-up power | 25kw | 30kw | 36kw | 44kw | 50kw | 55kw | 65kw | 93kw | |
Running power | 12kw | 13kw | 14.8kw | 17.9kw | 20kw | 22kw | 26kw | 38kw | |
Background Concentration Of formaldehyde |
Less than 15ug/m³,minimum value:6ug/m³ | ||||||||
Recovery rate |
More than 90% | ||||||||
Air Purification system |
Standard configurations | ||||||||
Size of climate chamber |
Customized |
Model | VOC-3000 | VOC-5000 | VOC-8000 | VOC-10000 | VOC-12000 | VOC-15000 | VOC-24000 | VOC-30000 | VOC-72000 |
Environment temperature |
5ºC~35ºC | ||||||||
Environment humidity |
≤90%RH | ||||||||
Environment requirements |
With no pollution source,TVOC≤500ug/m³ | ||||||||
Size of Climate Chamber (W×D×H)mm |
1500 ×1350 ×1500 |
1670 ×1500 ×2000 |
2000 ×1600 ×2500 |
2500 ×1600× 2500 |
3000 ×1600 ×2500 |
3200 ×2000 ×2500 |
3000 ×32000 ×2500 |
3000 ×4000 ×2500 |
3000 ×6000 ×4000 |
Size of Testing Chamber door(H×W)mm |
1200×800 | 1800×900 | 1900×900 | 1900×1100 | |||||
Temperature adjustment range |
15ºC~40ºC,more than 250ºC for high-temperature cleaning | ||||||||
Humidity adjustment range |
40~60%RH(20~30ºC) | ||||||||
Pressure | 10±5pa | ||||||||
Temperature fluctuation |
±0.3ºC | ||||||||
Temperature deviation |
±0.5ºC | ||||||||
Humidity fluctuation |
±2.5%RH | ||||||||
Humidity deviation |
3% | ||||||||
Air exchange rate |
0.2~2 times/h,±5%(High air exchange rates are available) | ||||||||
Air velocity | 0.1m/s~0.3m/s | ||||||||
Power supply |
AC 380V/50Hz/Three-phase four-wire/five-wire | ||||||||
Start-up power |
25kw | 30kw | 36kw | 44kw | 50kw | 55kw | 65kw | 93kw | |
Running power | 12kw | 13kw | 14.8kw | 17.9kw | 20kw | 22kw | 26kw | 38kw | |
Background concentration Of formaldehyde |
Less than 15ug/m³,minimum value:6ug/m³ | ||||||||
Recovery rate |
More than 80% | ||||||||
Air purification system | Standard configurations |
Suppliers with verified business licenses