Type: | Pressure Waterproof Tester |
---|---|
Loading Method: | Dynamic Load |
Display: | Digital |
Weight: | 100-500Kg |
Power Source: | AC220V |
Inner Chamber Size: | Diameter 1000*H 1000mm |
Customization: |
---|
Suppliers with verified business licenses
1,Description | IPX8 Water soaking and Pressure immersion test equipment | |||
2,Model No | IPX8-800L | |||
3,Pictures | ||||
4,Introduction & Applications | Introduction:The nature water(Rain,Sea water and River water)destroy the products and material,economic losses are difficult to estimate.The nature water make the products corrovie,dicolored,distorted,reduction in strength,inflated,and moldy.,etc,specially make electrical products short circuits and trigger fire disaster.Soit is necessary step to test the waterproof of products and materials. It is applied to electrical and electronic products, lamps and lanterns, electrical cabinet, electrical components, automobile, motorcycle and its spare parts and other products |
|||
Fucntions:Applied to electrical and electronic products, lamps and lanterns, electrical cabinet, electrical components, automobile, motorcycle and its spare parts and other products.After waterproof test,we can judge if the functions of products can meet the standard,and to improve the designs,improvements and inspection standard. |
||||
5,Corresponding Standard | IEC60529:1989 +A1:1999 +A2:2013 Degrees of protection provided by enclosures(IP Code),GB4208-2008 | |||
5,Dedicated silicone seal ring, good flexibility,no rapid wear. 6,Tank cap of device used12 pieces runners screw retainer(Delivery with assist steel bar). 7,Both side of tank assembly cylinder lifting device,smooth go up and down,relieve users' operating pressure. 8,Device install safety valve,automatic pres-relief when exceed rated power,prevent operator misoperation,setting excess process pressure. 9,Electronic control component used import brand(Like:LG,Panasonic,omoron ect.);Pneumatic component used Tiawan AirTAC,insure devices' working stability and service life. 10,Testing time setting:0-999 min,autostop supply pressure when arrive the testing time, and automatic drain the air of inner tank,tester can open the tank cap and take out the sample. 11,Pressure display:go through pressure sensor display pressure, and can automatic stability inner pressure;pressure sensor error value is±0.002Mpa,display accuracy is 0.001Mpa. 12,Flooding and water draining valve install at the bottom of the device. |
||||
7,Technical parameters | Structural Parameter | |||
Exterior chamber size | About D1100*W1080*H1550mm | |||
Inner chamber size | Diameter 1000*H 1000mm | |||
Tank thickness | 3mm | |||
Tank material | Stainless steel | |||
Flange thickness | 20mm | |||
Flange material | Stainless steel | |||
Weight | About 350KG | |||
Function Parameter | ||||
Pressure control method | Self-regulation | |||
Pressure sensor display accuracy | 0.001 Mpa | |||
Pressure sensor error range | ±0.002Mpa | |||
Test depth of water range | 0-50 meter | |||
Pressure setting range | 0.00-0.5Mpa | |||
Safety valve exhaust pressure | 0.55Mpa | |||
Maximum limit pressure | 0.6Mpa | |||
Testing time setting range | 0-999 min | |||
Safety device | Pressure safety valve protection,electric leakage switch protection. | |||
Pressure adjustment mode | Sensor setting value | |||
Electric Parameter | ||||
Voltage | 220V | |||
Power | 100W | |||
6.Main configuration table | Designation | Specification | Quantity | Brand/Remark |
Tank | Stainless steel self made | 1Piece | GRANDE | |
Case | Stainless steel self made | 1Piece | GRANDE | |
Time relay | 1Piece | Anliang | ||
Relay | 1 piece | Omron | ||
Electric leakage switch | 1 piece | LG | ||
Solenoid valve | 2 piece | Airtac | ||
Button switch | 3 piece | Hongbo | ||
Electronic control wire | 1 lot | / | ||
Cylinder | 2 Stripe | / | ||
Pressure regulating valve | 1 piece | Airtac | ||
Pressure meter | Oil immersed type/2.5 grade | 1 piece | Zastava | |
Pressure sensor | Display accuracy 0.001Mpa | 1 piece | Panasonic | |
Switched-mode powersupply | 1 piece | Omron | ||
9,Accessories | 1. Operting instruction one unit; 2. Factory certificate one unit; 3. Device warranty card one unit; 4. Safety valve certificate on unit; 5. Assist steel bar one root; 6.Water pipe one stripe(5 meter); 7.Intake one stripe. |
|||
10.Service Conditon | User guarantee the following below conditon,and fulfill corresponding link | |||
10.1. Using Field | Ground surface levelling,drainage expedite,ground and wall waterproof treatment ,setting floor drain or drain Ground load-carrying no less than 200kg/m2 Site excellent ventilation Around device no strong vibration Around no flammable,explosive,corrosive substance and dust Around device have appropriate use and maintain space: After side device,left and right side,top:600mm;front side of device:1000mm |
|||
10.2.Environmental Condition | Temperature:5ºC~35ºC Relative humidity:≤85% Air pressudre:86kPa~106kPa |
|||
10.3 Power Supply Condition | 220V Power voltage | |||
10.4 Water Source Condition | Running water/Purified water | |||
10.5 Air Source Condition | Used owned air compressor,advice output air pressure:0.6Mpa-0.8Mpa. |
Not protected | No | No |
Dripping water | Dripping water (vertically falling drops) shall have no harmful effect. | Test duration: 10minutes Water equivalent to 1 mm rainfall per minute |
Dripping water when tilted up to 15° | Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15° from its normal position. | Test duration: 10minutes Water equivalent to 3mm rainfall per minute |
Spraying water | Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect. | Test duration: 5 minutes Water volume: 0.7 litres per minute Pressure: 80- 100 kPa |
Splashing water | Water splashing against the enclosure from any direction shall have no harmful effect. | Test duration: 5 minutes Water volume: 10 litres per minute Pressure: 80- 100 kPa |
Water jets | Water projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects. | Test duration: at least 3 minutes Water volume: 12.5 litres per minute Pressure: 30 kPa at distance of 3 m |
Powerful water jets | Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects. | Test duration: at least 3 minutes Water volume: 100 litres per minute Pressure: 100 kPa at distance of 3 m |
Immersion up to 1 m | Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion). | Test duration: 30 minutes Immersion at depth of at least 1 m measured at bottom of device, and at least 15 cm measured at top of device |
Immersion beyond 1 m | The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. | Test duration: continuous immersion in water Depth specified by manufacturer |
IPX test grade | Test method | Time | Test standard | Remarks |
IPX7 | The cofferdam is soaked into the water,and keep the water is 15mm higher than top side of cofferdam ,and keep bottom of cofferdam at least 1000mm under water | 30 mins | 14.2.7 | |
IPX8 | The cofferdam is custom. The water height is decided by customer and GRANDE |
14.2.8 |
IP indication | Solid particle protection | Liquid ingress protection | Mechanical impact resistance | Other protections |
IP | Single numeral: 0-6 | Single numeral: 0-9 | Single numeral: 0-9 | Single letter |
Mandatory | Mandatory | Mandatory | No longer used | Optional |
Level sized | Effective against | Description |
0 | - | No protection against contact and ingress of objects |
1 | >50 mm | Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part |
2 | >12.5 mm | Fingers or similar objects |
3 | >2.5 mm | Tools, thick wires, etc. |
4 | >1 mm | Most wires, slender screws, large ants etc. |
5 | Dust protected | Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment. |
6 | Dust tight | No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow. |
Level | Protection against | Effective against | Details |
0 | None | - | - |
1 | Dripping water | Dripping water (vertically falling drops) shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM. | Test duration: 10 minutesWater equivalent to 1 mm rainfall per minute |
2 | Dripping water when tilted at 15° | Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes. | Test duration: 2.5 minutes for every direction of tilt (10 minutes total)Water equivalent to 3 mm rainfall per minute |
3 | Spraying water | Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. | For a Spray Nozzle:Test duration: 1 minute per square meter for at least 5 minutes[2] Water volume: 10 litres per minute Pressure: 50-150 kPaFor an oscillating tube:Test duration: 10 minutesWater Volume: 0.07 l/min per hole |
4 | Splashing of water | Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield.Test a) is conducted for 10 minutes. Test b) is conducted (without shield) for 5 minutes minimum. | Oscillating tube: Test duration: 10 minutes, or spray nozzle (same as IPX3 spray nozzle with the shield removed) |
5 | Water jets | Water projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects. | Test duration: 1 minute per square meter for at least 15 minutesWater volume: 12.5 litres per minute Pressure: 30 kPa at distance of 3 m |
6 | Powerful water jets | Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects. | Test duration: 1 minute per square meter for at least 3 minutesWater volume: 100 litres per minute Pressure: 100 kPa at distance of 3 m |
6K | Powerful water jets with increased pressure | Water projected in powerful jets (6.3 mm nozzle) against the enclosure from any direction, under elevated pressure, shall have no harmful effects. Found in DIN 40050, and not IEC 60529. | Test duration: at least 3 minutes[citation needed]Water volume: 75 litres per minute Pressure: 1000 kPa at distance of 3 m |
7 | Immersion, up to 1 m depth | Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion). | Test duration: 30 minutes - ref IEC 60529, table 8.Tested with the lowest point of the enclosure 1000 mm below the surface of the water, or the highest point 150 mm below the surface, whichever is deeper. |
8 | Immersion, 1 m or more depth | The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. The test depth and/or duration is expected to be greater than the requirements for IPx7, and other environmental effects may be added, such as temperature cycling before immersion. | Test duration: Agreement with ManufacturerDepth specified by manufacturer, generally up to 3 m |
9K | Powerful high temperature water jets | Protected against close-range high pressure, high temperature spray downs.Smaller specimens rotate slowly on a turntable, from 4 specific angles. Larger specimens are mounted upright, no turntable required, and are tested freehand for at least 3 minutes at distance of 0.15-0.2 m.There are specific requirements for the nozzle used for the testing.This test is identified as IPx9 in IEC 60529. | Test duration: 30 seconds in each of 4 angles (2 minutes total)Water volume: 14-16 litres per minute Pressure: 8-10 MPa (80-100 bar) at distance of 0.10-0.15 m Water temperature: 80 °C |
Letter | Meaning |
f | Oil resistant |
H | High voltage device |
M | Device moving during water test |
S | Device standing still during water test |
W | Weather conditions |
Approximate IK equivalents to IP drop level | |||||||
Dropped IP level |
Impact energy (J) |
Equivalent impact | IK number |
Impact energy (J) |
Equivalent impact | ||
0 | - | - | 00 | Unprotected | No test | ||
01 | 0.15 | 200 g dropped through 7.5 cm | |||||
1 | 0.225 | 150 g dropped through 15 cm | 02 | 0.2 | 200 g dropped through 10 cm | ||
2 | 0.375 | 250 g dropped through 15 cm | 03 | 0.35 | 200 g dropped through 17.5 cm | ||
3 | 0.5 | 250 g dropped through 20 cm | 04 | 0.5 | 200 g dropped through 25 cm | ||
05 | 0.7 | 200 g dropped through 35 cm | |||||
06 | 1 | 500 g dropped through 20 cm | |||||
5 | 2 | 500 g dropped through 40 cm | 07 | 2 | 500 g dropped through 40 cm | ||
7 | 6 | 1.5 kg dropped through 40 cm | 08 | 5 | 1.7 kg dropped through 29.5 cm | ||
09 | 10 | 5 kg dropped through 20 cm | |||||
9 | 20 | 5.0 kg dropped through 40 cm | 10 | 20 | 5 kg dropped through 40 cm |
NEMA enclosure | IP Code |
1 | IP20 |
2 | IP22 |
3, 3X, 3S, 3SX | IP55 |
3R, 3RX | IP24 |
4, 4X | IP66 |
5 | IP53 |
6 | IP67 |
6P | IP68 |
12, 12K, 13 | IP54 |
Suppliers with verified business licenses