Max Diameter of Workpiece: | 1200mm |
---|---|
Mass Scope of Workpiece: | <900kg |
Type: | Universal Testing Machine |
Maxcapacity: | <1000KN |
Accuracy Grade: | 0.5 |
Load Way: | Electronic Load |
Customization: |
---|
Suppliers with verified business licenses
Model No | GTH-080 | GTH-150 | GTH-225 | GTH-408 | GTH-800 | GTH-1000 | ||||
Working room(L) | 80 | 150 | 225 | 408 | 800 | 1000 | ||||
Inner chamber size(mm)W*H*D | 400*500*400 | 500*600*500 | 500*750*600 | 600*850*800 | 1000*1000*800 | 1000*1000*1000 | ||||
Exterior chamber size(mm)W*H*D | 900*900*1500 | 950*1500*1050 | 950*1650*1150 | 1050*1750*1350 | 1450*1900*1350 | 1450*1900*1550 | ||||
Packaging volume(CBM) | 2 | 3 | 3.5 | 4.5 | 5.5 | 6 | ||||
G.W.(KGs) | 300 | 320 | 350 | 400 | 600 | 700 | ||||
Performance | Temperature range | -160ºC,-150ºC,-120ºC,-100ºC,-80ºC,-70ºC,-60ºC,-40ºC,-20ºC,0ºC~+150ºC,200ºC,250ºC,300ºC, 400ºC,500ºC |
||||||||
Humidity range | 20%RH ~98%RH(10%RH ~98%RH or 5%RH ~98%RH) | |||||||||
Temp.&Humi fluctuation | ±0.2°C, ±0.5%RH | |||||||||
Temp.Humi.Uniformity | ±1.5°C; ±2.5%RH(RH≤75%),±4%RH(RH>75%) No-load operation,After stead state 30 min. (±1.5°C; ±1%RH(RH≤75%) |
|||||||||
Temp.humi resolution | 0.01°C; 0.1%RH | |||||||||
Heating up time | °C | 100 150 | ||||||||
Min | 30 40 | 30 40 | 30 45 | 30 45 | 30 45 | 30 45 | ||||
Cooling down time | °C | 0 -20 -40 -60 -70 | ||||||||
Min | 25 40 50 70 80 | |||||||||
Heating rate | ≥3°C/min | |||||||||
Cooling rate | ≥1°C/min | |||||||||
Heating & Cooling Rate (Options) |
1°C/min,3°C/min, 5°C/min, 8°C/min, 10°C/min, 15°C/min,20°C/min,25°C/min,30°C/min linear average or nonlinear average |
|||||||||
Material | Inner chamber material | SUS#304 stainless steel plate | ||||||||
Exterior chamber material | SUS304 Stainless steel plate+ powder coated | |||||||||
Insulation Material | PU & Fiberglass wool | |||||||||
System | Air circulation system | Cooling fan | ||||||||
Fan | Sirocco fan | |||||||||
Heating System | SUS#304 stainless steel high-speed heater | |||||||||
Air flow | Forced Air Circulation(It enters at bottom and leaves at top) | |||||||||
Humidification system | Surface evaporation system | |||||||||
Refrigeration system | Imported compressor,French Tecumseh compressor or German Bitzer compressor,finned type evaporator,air(Water)-cooling condenser | |||||||||
Refrigerating fluid | R23/ R404A USA Honeywell. | |||||||||
Condensation | Air(Water)-cooling condenser | |||||||||
Dehumidifying system |
ADP critical dew point cooling/dehumidifying method |
|||||||||
Controlling system |
PID Digital electronic indicators+S.S.R.With PID automatic calculation capability |
|||||||||
Operation interface |
Grande Expertise in Temperature & Humidity Controller,Chinese-English Shift. |
|||||||||
Controller | Programmable capability | Save 120 profiles with up to 1200 steps each | ||||||||
Setting range | Temperature:-100ºC+300ºC | |||||||||
Reading accuracy | Temperature:0.01ºC | |||||||||
Input | PT100 or T Sensor | |||||||||
Control | PID control | |||||||||
Communication interface | Equipped with standard communication interface devices USB,RS-232 and RS-485,enable the test chamber to be connected with personal computer(PC),to achieve multi-machine control and management at the same time.Standard: USB external memory port.Optional: RS-232, RS-485, GP-IB, Ethernet | |||||||||
Print function | Japan Yokogawa Temperature Recorder(Optional accessories) | |||||||||
Auxiliary | Limit Alarm,Self Diagnosis,Alarm Display(Failure Cause),Timing device(Automatic Switch) | |||||||||
Accessories | Multi-layer vacuum glass observation window,Cable port(50mm),Controlling status indicator lamp,Chamber light,Specimen loading shelf(2pcs,position adjustable),Guaze 5pcs,Operation manual 1 set. | |||||||||
Safety protection device | Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp. | |||||||||
Power supply | AC 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50Hz | |||||||||
Customized service | Welcome to Non-standard,Specail requirements,OEM/ODM orders. | |||||||||
The technical information will be subjected to change without notice |
Suppliers with verified business licenses